Validation of the Brazilian version of the Pediatric Obstructive Sleep Apnea Screening Tool questionnaire

To validate the Pediatric Obstructive Sleep Apnea Screening tool for use in Brazil. The Brazilian version of this questionnaire, originally validated and tested in the United States, was developed as follows: (a) translation; (b) back-translation; (c) completion of the final version; (d) pre-testing...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Jornal de pediatria 2019-03, Vol.95 (2), p.231-237
Hauptverfasser: Pires, Priscila J.S., Mattiello, Rita, Lumertz, Magali S., Morsch, Thiago P., Fagondes, Simone C., Nunes, Magda L., Gozal, David, Stein, Renato T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To validate the Pediatric Obstructive Sleep Apnea Screening tool for use in Brazil. The Brazilian version of this questionnaire, originally validated and tested in the United States, was developed as follows: (a) translation; (b) back-translation; (c) completion of the final version; (d) pre-testing. The questionnaire was applied prior to polysomnography to children aged 3–9 years from October 2015 to October 2016, and its psychometric properties (i.e., validity and reliability) were evaluated. The accuracy was assessed from comparisons between polysomnographic results and corresponding questionnaire scores. Sixty patients were enrolled, and based on polysomnographic findings, 48% patients had normal apnea-hypopnea index, while the remaining 52% met the criteria for obstructive sleep apnea. Minimum O2 saturation level was significantly lower among obstructive sleep apnea children (p=0.021). Satisfactory concordance was found between individual apnea-hypopnea index and questionnaire scores. Bland–Altman plot-derived bias was 0.1 for the difference between measures, with 5.34 (95% CI: 4.14–6.55) and −5.19 (95%CI: −6.39 to −3.98) for the upper and lower agreement range. Internal consistency derived from Cronbach's alpha was 0.84 (95%CI: 0.78–0.90). The questionnaire was translated to and validated into Brazilian-Portuguese version, and showed good reliability and concordance with apnea-hypopnea index. This questionnaire offers a reliable screening option for sleep-disordered breathing in children. Validar o questionário Pediatric Obstructive Sleep Apnea Screening Tool para o seu uso no Brasil. A versão brasileira desse questionário, originalmente validado e testado nos Estados Unidos, foi desenvolvida a partir das seguintes etapas: a) tradução; b) retro-tradução; c) conclusão da versão final; d) pré-teste. O questionário foi aplicado previamente ao início da polissonografia em crianças de 3 a 9 anos incluídas no estudo no período de outubro de 2015 a outubro de 2016. As propriedades psicométricas avaliadas foram validade e confiabilidade. A acurácia foi avaliada pela comparação entre os resultados da polissonografia com o escore do questionário. Foram incluídos no estudo 60 pacientes. Conforme a polissonografia, 48% dos pacientes apresentaram índices de apneia e hipopneia normais e 51% apresentaram resultados alterados. A SpO2 mínima foi significativamente menor (p = 0,021) nas crianças com diagnóstico de síndrome de apneia obstrutiva do sono. O índice de apn
ISSN:0021-7557
1678-4782
1678-4782
DOI:10.1016/j.jped.2017.12.014