Total Hip Arthroplasty Using a Hemispherical Uncemented Dual-Mobility Cup Results in Satisfactory Clinical Outcomes and No Dislocations at 2 years
The authors performed total hip arthroplasty (THA) using a novel hemispherical dual-mobility (DM) acetabular cup without a protrusive cylindro-spherical rim, intended to reduce risks of iliopsoas impingement without requiring changes to conventional intraoperative positioning as with unipolar cups....
Gespeichert in:
Veröffentlicht in: | Arthroplasty today 2021-06, Vol.9, p.93-97 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The authors performed total hip arthroplasty (THA) using a novel hemispherical dual-mobility (DM) acetabular cup without a protrusive cylindro-spherical rim, intended to reduce risks of iliopsoas impingement without requiring changes to conventional intraoperative positioning as with unipolar cups. We aim to determine clinical scores and rates of dislocations, complications, and revisions of this hemispherical DM cup, with the hypothesis that this novel design would result in clinical scores and dislocation rates comparable to other contemporary DM cups with protrusive cylindro-spherical rims.
We assessed 332 consecutive uncemented THAs performed using a hemispherical DM cup, at a minimum 2-year follow-up, using modified Harris Hip Score (mHHS) and Oxford Hip Score (OHS), and noting complications and revisions. Regression analyses were conducted to determine if mHHS and OHS depended on any independent factors.
At 2.8 ± 0.5 years (range, 2–5), 2 patients (0.6%) had stem and cup revisions, 3 patients (1%) had isolated stem revisions, 13 patients (4%) died, and none were lost to follow-up. No dislocations occurred. For the final cohort of 305 patients (314 hips) with their original implants in place, mHHS was 92 ± 12 (range, 46–100), and OHS was 57 ± 5 (range, 34–60). Multivariable analyses revealed that mHHS and OHS decreased significantly with age (β = -0.35, P < .001, and β = -0.15, P < .001, respectively).
With no dislocations and satisfactory clinical scores, this sizable cohort confirms that the novel hemispherical DM cup studied is effective at preventing dislocations, although longer-term follow-up remains necessary to ascertain the longevity of clinical outcomes and radiographic stability.
Level IV, multicentric retrospective case series. |
---|---|
ISSN: | 2352-3441 2352-3441 |
DOI: | 10.1016/j.artd.2021.04.017 |