The effect and mechanism of iodophors on the adhesion and virulence of Staphylococcus aureus biofilms attached to artificial joint materials

Background Iodophors are known to be a treatment for biofilm-related periprosthetic joint infection. However, the efficacy and mechanism of eradicating biofilms from different artificial joint materials after iodophor treatment are unknown. This study was conducted to understand the effect and mecha...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of orthopaedic surgery and research 2023-10, Vol.18 (1), p.1-756, Article 756
Hauptverfasser: Chen, Sihui, Jiang, Yi, Wang, Wei, Chen, Junjie, Zhu, Jinyu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Iodophors are known to be a treatment for biofilm-related periprosthetic joint infection. However, the efficacy and mechanism of eradicating biofilms from different artificial joint materials after iodophor treatment are unknown. This study was conducted to understand the effect and mechanism of iodophors with respect to the adhesion and virulence of Staphylococcus aureus biofilms attached to artificial joint materials. Methods Biofilms of Staphylococcus aureus strains were grown on titanium alloy, cobalt chromium molybdenum and polyethylene coupons, which are commonly used materials for artificial joints, for 24 h. Afterward, all coupons were divided into experimental and control groups: (1) exposed to a 0.5 [+ or -] 0.05% iodophor for 5 min and (2) exposed to phosphate-buffered saline for 5 min. To gauge the level of biofilm, colony forming units (CFU), live/dead staining confocal microscopy and crystal violet staining were used. Meanwhile, the expression of icaACDR and clfA, which are related to virulence and adhesion, was examined in both the experimental and control groups. Results A roughly three-log decrease in CFU/cm.sup.2 was seen in the viable plate count compared to the control group. Confocal imaging and crystal violet staining verified the CFU data. Moreover, the expression of icaACDR was reduced on three different orthopaedic implant materials, and the expression of clfA was also inhibited on titanium alloy coupons exposed to the iodophor. Conclusions Our results indicated that exposure to an iodophor for 5 min could significantly eliminate biofilms. When Staphylococcus aureus that had adhered to these three materials, which were used for artificial joints, was treated with an iodophor for 5 min, the expression of icaACDR was significantly reduced. This provides strong evidence for clinically clearing periprosthetic joint infections without removing the artificial joints. Keywords: Iodophor, Biofilm, Staphylococcus aureus, Artificial joint materials, Adhesion, Virulence
ISSN:1749-799X
1749-799X
DOI:10.1186/s13018-023-04246-x