Clinical outcomes of the Myval transcatheter heart valve system in patients with severe aortic valve stenosis: a two-year follow-up observational study

Limited data exist on long-term follow-up of severe aortic stenosis (SAS) patients who have undergone transcatheter aortic valve implantation (TAVI) with a new generation, balloon expandable Myval transcatheter heart valve (THV). Thus, we sought to investigate the performance and 2-year clinical out...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of medical science 2024-01, Vol.20 (2), p.410-419
Hauptverfasser: Kilic, Teoman, Ielasi, Alfonso, Ninios, Vlasis, Korkmaz, Levent, Panagiotakos, Demosthenes, Yerlikaya, Gokhan, Ozderya, Ahmet, Montonati, Carolina, Tespili, Maurizio, Coskun, Senol, Sahin, Tayfun, Ninios, Ilias, Vlasopoulou, Konstantina, Konus, Ali Hakan, Kul, Selim, Akyuz, Ali Riza
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Limited data exist on long-term follow-up of severe aortic stenosis (SAS) patients who have undergone transcatheter aortic valve implantation (TAVI) with a new generation, balloon expandable Myval transcatheter heart valve (THV). Thus, we sought to investigate the performance and 2-year clinical outcome of the Myval THV system based on Valve Academic Research Consortium-3 (VARC-3) criteria. A multi-centre, registry-based, observational study was conducted, which included 207 consecutive degenerative SAS patients, from Turkey ( = 128), Italy ( = 58), and Greece ( = 21) (mean [standard deviation] 81 (7) years, 94 [45%] men; 73% NYHA III or IV; EuroSCORE II 5.2% [2.4%]); all patients underwent TAVI with Myval. Patients were followed up at 1 year and 2 years after implantation. Clinical and procedural outcomes were defined according to VARC-3 criteria. Technical success was observed in 204 (99%), device success was observed in 189 (91%), early safety was observed in 161 (78%), and clinical efficacy was observed in 163 (79%) patients. The 30-day death rate was 7.7%; of these, 3.4% were due to cardiovascular reasons. All-cause and cardiovascular mortality rates were 9.7% and 4.3% at 1-year follow-up, and 17.4% and 9.7% at 2-year follow-up, respectively. Incidence of ≥ moderate paravalvular leak (PVL) at 30 days, 1 year and 2 years of follow-up were 3.4%, 4.3% and 4.8%. A total of 11.1% of patients required a permanent pacemaker implantation (PPI) at 30 days after implantation, while the cumulative rate of PPI at 2 years was 12.1%. In this cohort of patients with SAS, the Myval was found to be safe and effective in up to 2 years of follow-up.
ISSN:1734-1922
1896-9151
DOI:10.5114/aoms/176937