Automated surgical step recognition in transurethral bladder tumor resection using artificial intelligence: transfer learning across surgical modalities
Automated surgical step recognition (SSR) using AI has been a catalyst in the "digitization" of surgery. However, progress has been limited to laparoscopy, with relatively few SSR tools in endoscopic surgery. This study aimed to create a SSR model for transurethral resection of bladder tum...
Gespeichert in:
Veröffentlicht in: | Frontiers in artificial intelligence 2024, Vol.7, p.1375482-1375482 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Automated surgical step recognition (SSR) using AI has been a catalyst in the "digitization" of surgery. However, progress has been limited to laparoscopy, with relatively few SSR tools in endoscopic surgery. This study aimed to create a SSR model for transurethral resection of bladder tumors (TURBT), leveraging a novel application of transfer learning to reduce video dataset requirements.
Retrospective surgical videos of TURBT were manually annotated with the following steps of surgery: primary endoscopic evaluation, resection of bladder tumor, and surface coagulation. Manually annotated videos were then utilized to train a novel AI computer vision algorithm to perform automated video annotation of TURBT surgical video, utilizing a transfer-learning technique to pre-train on laparoscopic procedures. Accuracy of AI SSR was determined by comparison to human annotations as the reference standard.
A total of 300 full-length TURBT videos (median 23.96 min; IQR 14.13-41.31 min) were manually annotated with sequential steps of surgery. One hundred and seventy-nine videos served as a training dataset for algorithm development, 44 for internal validation, and 77 as a separate test cohort for evaluating algorithm accuracy. Overall accuracy of AI video analysis was 89.6%. Model accuracy was highest for the primary endoscopic evaluation step (98.2%) and lowest for the surface coagulation step (82.7%).
We developed a fully automated computer vision algorithm for high-accuracy annotation of TURBT surgical videos. This represents the first application of transfer-learning from laparoscopy-based computer vision models into surgical endoscopy, demonstrating the promise of this approach in adapting to new procedure types. |
---|---|