Preclinical Direct Endoluminal Assessment of Endothelialization After Flow Diversion With Microangioscopy
BackgroundDirect endoluminal imaging, such as with our previously described microangioscope, is an emerging adjunct in endovascular cerebral aneurysm management that enables clinicians to delineate between thrombi and visualize neoepithelialization after stent placement with high resolution. The pre...
Gespeichert in:
Veröffentlicht in: | Stroke: vascular and interventional neurology 2024-09, Vol.4 (5) |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | BackgroundDirect endoluminal imaging, such as with our previously described microangioscope, is an emerging adjunct in endovascular cerebral aneurysm management that enables clinicians to delineate between thrombi and visualize neoepithelialization after stent placement with high resolution. The present study sought to study flow diversion in vivo under direct endoluminal imaging, and to validate our findings with histopathology.MethodsIn a rabbit model, we implanted each left common carotid artery with a shielded flow diverter (FD) (Medtronic Pipeline Vantage) and nonshielded FD (Medtronic Pipeline Flex) in the right common carotid artery. We studied 9 animals in 3 groups: (1) no periprocedural antiplatelet therapy, (2) aspirin 81 mg daily, and (3) aspirin 81 mg and clopidogrel 75 mg daily. FD thrombosis, stenosis, malapposition, and neoepithelialization were all evaluated by diagnostic cerebral angiography and microangioscopy after 30 days. Diagnostic cerebral angiography and angioscopic video were analyzed by independent evaluators and compared with histopathologic analysis.ResultsIn the aspirin and dual antiplatelet therapy groups, there were no significant observed differences in stent thrombosis, stenosis, malapposition, or neoepithelialization between the shielded and non‐shielded FD groups. There was significantly more thrombus formation in Group 1. Neointimal thickness as measured by the microangioscope was highly correlated with histology (r = 0.72; P = 0.016). Interrater agreement of microangioscope videos was highest for FD thrombosis and stenosis.ConclusionIn‐stent thrombosis, stenosis, malapposition, and neopithelialization demonstrated no significant difference between shielded and non‐shielded FDs. Microangioscopy measurements for neointimal thickness were highly correlated with pathology and may be a helpful adjunct to diagnostic cerebral angiography in FD follow‐up. |
---|---|
ISSN: | 2694-5746 2694-5746 |
DOI: | 10.1161/SVIN.124.001340 |