An integrated evaluation approach of wearable lower limb exoskeletons for human performance augmentation

Wearable robots have been growing exponentially during the past years and it is crucial to quantify the performance effectiveness and to convert them into practical benchmarks. Although there exist some common metrics such as metabolic cost, many other characteristics still needs to be presented and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scientific reports 2023-03, Vol.13 (1), p.4251-4251, Article 4251
Hauptverfasser: Zhang, Xiao, Chen, Xue, Huo, Bo, Liu, Chenglin, Zhu, Xiaorong, Zu, Yuanyuan, Wang, Xiliang, Chen, Xiao, Sun, Qing
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Wearable robots have been growing exponentially during the past years and it is crucial to quantify the performance effectiveness and to convert them into practical benchmarks. Although there exist some common metrics such as metabolic cost, many other characteristics still needs to be presented and demonstrated. In this study, we developed an integrated evaluation (IE) approach of wearable exoskeletons of lower limb focusing on human performance augmentation. We proposed a novel classification of trial tasks closely related to exoskeleton functions, which were divided into three categories, namely, basic trial at the preliminary phase, semi-reality trial at the intermediate phase, and reality trial at the advanced phase. In the present study, the IE approach has been exercised with a subject who wore an active power-assisted knee (APAK) exoskeleton with three types of trial tasks, including walking on a treadmill at a certain angle, walking up and down on three-step stairs, and ascending in 11-storey stairs. Three wearable conditions were carried out in each trial task, i.e. with unpowered exoskeleton, with powered exoskeleton, and without the exoskeleton. Nine performance indicators (PIs) for evaluating performance effectiveness were adopted basing on three aspects of goal-level, task-based kinematics, and human–robot interactions. Results indicated that compared with other conditions, the powered APAK exoskeleton make generally lesser heart rate (HR), Metabolic equivalent (METs), biceps femoris (BF) and rectus femoris (RF) muscles activation of the subject at the preliminary phase and intermediate phase, however, with minimal performance augmentation at advanced phase, suggesting that the APAK exoskeleton is not suitable for marketing and should be further improved. In the future, continuous iterative optimization for the IE approach may help the robot community to attain a comprehensive benchmarking methodology for robot-assisted locomotion more efficiently.
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-023-29887-0