Polymorphism analysis of tri- and tetranucleotide repeat microsatellite markers in Hanwoo cattle

The Hanwoo traceability system currently utilizes 11 dinucleotide repeat microsatellite (MS) markers. However, dinucleotide repeat markers are known to have a high incidence of polymerase chain reaction (PCR) artifacts, such as stutter bands, which can complicate the accurate reading of alleles. In...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of animal science and technology 2024-07, Vol.66 (4), p.717-725
Hauptverfasser: Jin, Shil, Won, Jeong Il, Kim, Hyoun Ju, Park, Byoungho, Kim, Sung Woo, Kim, Ui Hyung, Kang, Sung-Sik, Lee, Hyun-Jeong, Moon, Sung Jin, Park, Myung Sun, Sim, Yong Teak, Jang, Sun Sik, Kim, Nam Young
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The Hanwoo traceability system currently utilizes 11 dinucleotide repeat microsatellite (MS) markers. However, dinucleotide repeat markers are known to have a high incidence of polymerase chain reaction (PCR) artifacts, such as stutter bands, which can complicate the accurate reading of alleles. In this study, we examined the polymorphisms of the 11 dinucleotide repeat MS markers currently employed in traceability systems. Additionally, we explored four trinucleotide repeat MS markers and one tetranucleotide repeat MS marker in a sample of 1,106 Hanwoo cattle. We also assessed the potential utility of the tri- and tetranucleotide repeat MS markers. The polymorphic information content (PIC) of the five tri- and tetranucleotide repeat markers ranged from 0.663 to 0.767 (mean: 0.722), sufficiently polymorphic and slightly higher than the mean (0.716) of the current 11 dinucleotide repeat markers. Using all 16 markers, the mean PIC was 0.718. The estimated probability of identity (PI) was 3.13 × 10 using the 11 dinucleotide repeat markers, 7.03 × 10 using the five tri- and tetranucleotide repeat markers, and 2.39 × 10 using all 16 markers; the respective PI values were 2.69 × 10 , 1.29 × 10 , and 3.42 × 10 ; and the respective PIsibs values were 3.89 × 10 , 9.6 × 10 , and 3.69 × 10 . The probability of exclusion (PE ) was 0.999864 for the 11 dinucleotide repeat markers, 0.981141 for five of the tri- and tetranucleotide repeat markers, and > 0.99 for all 16 markers; the respective PE values were 0.994632, 0.901369, and > 0.99; and the respective PE values were 0.998702, > 0.99, and > 0.99. The five investigated tri- and tetranucleotide repeat MS markers can be used in combination with the 11 existing MS markers to improve the accuracy of individual identification and paternity testing in Hanwoo.
ISSN:2055-0391
2672-0191
2093-6281
DOI:10.5187/jast.2024.e10