Coil volume embolization ratio for preventing recanalization after portal vein embolization

The purpose of this study was to evaluate the optimum volume embolization ratio (VER) for the prevention of recanalization after portal vein embolization (PVE) and the influence of recanalization on future liver remnant (FLR) function using technetium-99m galactosyl human serum albumin single-photon...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostic and interventional radiology (Ankara, Turkey) Turkey), 2021-05, Vol.27 (3), p.366-371
Hauptverfasser: Maruyama, Mitsunari, Yoshizako, Takeshi, Ando, Shinji, Nakamura, Megumi, Tajima, Yoshitsugu, Kitagaki, Hajime
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The purpose of this study was to evaluate the optimum volume embolization ratio (VER) for the prevention of recanalization after portal vein embolization (PVE) and the influence of recanalization on future liver remnant (FLR) function using technetium-99m galactosyl human serum albumin single-photon emission computed tomography (99mTc-GSA SPECT/CT) fusion imaging. We analyzed procedural data of 18 patients who underwent PVE from 2015 to 2018. A total of 29 portal branches were embolized (12 anterior branch, 11 posterior branch, 4 left branch, 2 right branch) with absolute ethanol and coils. Portal vein recanalization was evaluated three weeks after PVE by contrast-enhanced CT. We classified the treated portal branches as non-recanalized and recanalized. VER was compared between the groups. In addition, for each patient, we calculated and evaluated the ratio of FLR volume to total liver volume (volumetric %FLR), FLR count to total liver count on 99mTc-GSA SPECT/CT fusion imaging (functional %FLR), and functional-volumetric ratio (functional %FLR/ volumetric %FLR). Twenty-six portal branches showed no recanalization (non-recanalized group, n=26, 89.7%), while three portal branches showed recanalization (recanalized group, n=3, 10.3%). The median VER was 4.94% (3.12%-11.1%) in the non-recanalized group and 3.49% (2.76%-4.32%) in the recanalized group, which was significantly different between the groups (p = 0.045, Mann-Whitney U test). The median functional-volumetric ratio was 1.16 (1.03-1.50) in non-recanalized patients (n=15, 83.3%) and 1.01 (0.96-1.13) in recanalized patients (n=3, 16.7%), and it was significantly higher in the non-recanalized patients (p = 0.021, Mann-Whitney U test). The VER for preventing recanalization after PVE was approximately 5% (> 4.94%). 99mTc-GSA SPECT/CT fusion imaging revealed a decrease in FLR function due to recanalization after PVE.
ISSN:1305-3612
1305-3825
1305-3612
DOI:10.5152/dir.2021.20043