Experimental Nonlinear FE Modelling & Eurocode 3 Analyses of Steel Flush Endplate Joints

Structural steel joints form an integral part of all structural steel frames and regardless of the joint type employed the behaviour and response of the joints is of primary importance in determining the manner in which the frame resists both vertical and horizontal loading. An understanding of join...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electronic journal of structural engineering 2010-01, Vol.10, p.36-44
Hauptverfasser: Fanning, P J, Tucker, MJ
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Structural steel joints form an integral part of all structural steel frames and regardless of the joint type employed the behaviour and response of the joints is of primary importance in determining the manner in which the frame resists both vertical and horizontal loading. An understanding of joint stiffness, strength and ductility is required. Eurocode 3 provides guidance for predicting the ultimate strength, rotational capacity and rotational stiffness of steel flush endplate joints. This paper examines in detail the correlation be-tween Eurocode 3 predictions and actual behaviour recorded in full scale tests and validated numerical mod-els. The detailed three dimensional finite element analysis methods used enable the significant differences to be explained by reference to the initial assumptions made in the Eurocode 3 calculations.
ISSN:1443-9255
1443-9255
DOI:10.56748/ejse.10123