Temporal Variation of Ambient PM10 Concentration within an Urban-Industrial Environment

PM10 concentration in the ambient air has been reported to be the main pollutant affecting human health, particularly in the urban areas. This research is conducted to study the variation of PM10 concentration at the three urban-industrial areas in Malaysia, namely Shah Alam, Kuala Terengganu and Me...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:E3S Web of Conferences 2018-01, Vol.34, p.2002
Hauptverfasser: Wong, Yoon-Keaw, Mohamed Noor, Norazian, Mohamad Hashim, Nur Izzah
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PM10 concentration in the ambient air has been reported to be the main pollutant affecting human health, particularly in the urban areas. This research is conducted to study the variation of PM10 concentration at the three urban-industrial areas in Malaysia, namely Shah Alam, Kuala Terengganu and Melaka. In addition, the association and correlation between PM10 concentration and other air pollutants will be distinguished. Five years interval dataset (2008-2012) consisting of PM10, SOX, NOX and O3 concentrations and other weather parameters such as wind speed, humidity and temperature were obtained from Department of Environment, Malaysia. Shah Alam shows the highest average of PM10 concentration with the value of 62.76 μg/m 3 in June, whereas for Kuala Terengganu was 59.29 μg/m 3 in February and 46.61 μg/m 3 in August for Melaka. Two peaks were observed from the time series plot using the averaged monthly PM10 concentration. First peak occurs when PM10 concentration rises from January to February and the second peak is reached in June and remain high for the next two consecutive months for Shah Alam and Kuala Terengganu. Meanwhile the second peak for Melaka is only achieved in August as a result of the transboundary of smoke from forest fires in the Sumatra region during dry season from May to September. Both of the pollutants can be sourced from rapid industrial activities at Shah Alam. PM10 concentration is strongly correlated with carbon monoxide concentration in Kuala Terengganu and Melaka with value of r2 = 0.1725 and 0.2744 respectively. High carbon monoxide and PM10 concentration are associated with burning of fossil fuel from increased number of vehicles at these areas.
ISSN:2267-1242
2555-0403
2267-1242
DOI:10.1051/e3sconf/20183402002