Biomechanical comparison of bi- and tricortical k-wire fixation in tension band wiring osteosynthesis

Patients with a simple transversal fracture of the olecranon are often treated with a tension band wiring (TBW), because it is known as a biomechanically appropriate and cost-effective procedure. Nevertheless, the technique is in detail more challenging than thought, resulting in a considerable high...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of medical research 2019-10, Vol.24 (1), p.33-33, Article 33
Hauptverfasser: Nowotny, J, Bischoff, F, Ahlfeld, T, Goronzy, J, Tille, E, Nimtschke, U, Biewener, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Patients with a simple transversal fracture of the olecranon are often treated with a tension band wiring (TBW), because it is known as a biomechanically appropriate and cost-effective procedure. Nevertheless, the technique is in detail more challenging than thought, resulting in a considerable high rate of implant-related complications like k-wire loosening and soft tissue irritation. In the literature, a distinction is generally only made between transcortical (bi-) and intramedullary (mono-) fixation of the wires. There is the additional possibility to fix the proximal bent end of k-wire in the cortex of the bone and thus create a tricortical fixation. The present study investigates the effectiveness of bi- and tricortical k-wire fixation in a biomechanical approach. TBW of the olecranon was performed at 10 cadaver ulnas from six donors in a usual manner and divided into two groups: In group 1, the k-wire was inserted by bicortical fixation (BC), and in group 2, a tricortical fixation (TC) was chosen. Failure behavior and maximum pullout strength were assessed and evaluated by using a Zwick machine. The statistical evaluation was descriptive and with a paired t test for the evaluation of significances between the two techniques. The average age of the used donors was 81.5 ± 11.5 (62-92) years. Three donors were female, and three were male. Ten k-wires were examined in BC group and 10 in the TC group. The mean bone density of the used proximal ulnas was on average 579 ± 186 (336-899) HU. The maximum pullout strength was 263 ± 106 (125-429) N in the BC group and increased significantly in the TC group to 325 ± 102 (144-466) N [p = .005]. This study confirms for the first time biomechanical superiority of tricortical k-wire fixation in the olecranon when using a TBW and may justify the clinical use of this method.
ISSN:2047-783X
0949-2321
2047-783X
DOI:10.1186/s40001-019-0392-7