Evaluation of fluorimetry and direct visualization to interpret results of a loop-mediated isothermal amplification kit to detect Leishmania DNA

Nucleic acid amplification tests (NAATs) have proven to be advantageous in the diagnosis of leishmaniases, allowing sensitive diagnosis of: (i) cutaneous leishmaniasis in long duration lesions and (ii) visceral leishmaniasis using a less-invasive sample like peripheral blood, in opposition to tissue...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Parasites & vectors 2018-04, Vol.11 (1), p.250-250, Article 250
Hauptverfasser: Ibarra-Meneses, Ana V, Cruz, Israel, Chicharro, Carmen, Sánchez, Carmen, Biéler, Sylvain, Broger, Tobias, Moreno, Javier, Carrillo, Eugenia
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Nucleic acid amplification tests (NAATs) have proven to be advantageous in the diagnosis of leishmaniases, allowing sensitive diagnosis of: (i) cutaneous leishmaniasis in long duration lesions and (ii) visceral leishmaniasis using a less-invasive sample like peripheral blood, in opposition to tissue aspiration required for parasite demonstration by microscopy. Despite their benefits, the implementation of NAATs for leishmaniasis diagnosis at the point-of-care has not been achieved yet, mostly due to the complexity and logistical issues associated with PCR-based methods. In this work, we have evaluated the performance of a ready-to-use loop-mediated isothermal amplification (LAMP) kit using two real time fluorimeters to amplify leishmanial DNA obtained by silica column-based and Boil & Spin protocols. The different approaches used to run and interpret the LAMP reactions showed a performance equivalent to PCR and real-time PCR, using spiked and clinical samples. The time to positivity obtained with real-time fluorimetry showed an excellent correlation with both Ct values and parasite load from real-time quantitative PCR. The results obtained open the possibility of using a highly stable, ready-to-use LAMP kit for the accurate diagnosis of leishmaniasis at the point-of-care. Furthermore, the feasibility of relating time to positivity, determined with a portable real-time fluorimeter, with the parasite burden could have a wider application in the management of leishmaniasis, such as in treatment efficacy monitoring or as a pharmacodynamics tool in clinical trials.
ISSN:1756-3305
1756-3305
DOI:10.1186/s13071-018-2836-2