Development of a Novel Multiplex PCR Method for the Rapid Detection of SARS-CoV-2, Influenza A Virus, and Influenza B Virus

Objective. A sensitive and specific multiplex fluorescence rapid detection method was established for simultaneous detection of SARS-CoV-2, influenza A virus, and influenza B virus in a self-made device within 30 min, with a minimum detection limit of 200 copies/mL. Methods. Based on the genome sequ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of analytical chemistry 2024-02, Vol.2024, p.4950391-9
Hauptverfasser: Ma, Liang, Zhu, Haoyan, Jiang, Yongwei, Kong, Xiaomu, Gao, Peng, Liu, Yi, Zhao, Meimei, Deng, Guoxiong, Cao, Yongtong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective. A sensitive and specific multiplex fluorescence rapid detection method was established for simultaneous detection of SARS-CoV-2, influenza A virus, and influenza B virus in a self-made device within 30 min, with a minimum detection limit of 200 copies/mL. Methods. Based on the genome sequences of SARS-CoV-2, influenza A virus (FluA), and influenza B virus (FluB) with reference to the Chinese Center for Disease Control and Prevention and related literature, specific primers were designed, and a multiplex fluorescent PCR system was established. The simultaneous and rapid detection of SARS-CoV-2, FluA, and FluB was achieved by optimizing the concentrations of Taq DNA polymerase as well as primers, probes, and Mg2+. The minimum detection limits of the nucleic acid rapid detection system for SARS-CoV-2, FluA, and FluB were evaluated. Results. By optimizing the amplification system, the N enzyme with the best amplification performance was selected, and the optimal concentration of Mg2+ in the multiamplification system was 3 mmol/L; the final concentrations of SARS-CoV-2 NP probe and primer were 0.15 μmol/L and 0.2 μmol/L, respectively; the final concentrations of SARS-CoV-2 ORF probe and primer were both 0.15 μmol/L; the final concentrations of FluA probe and primer were 0.2 μmol/L and 0.3 μmol/L, respectively; the final concentrations of FluB probe and primer were 0.15 μmol/L and 0.25 μmol/L, respectively. Conclusion. A multiplex real-time quantitative fluorescence RT-PCR system for three respiratory viruses of SARS-CoV-2, FluA, and FluB was established with a high amplification efficiency and sensitivity reaching 200 copies/mL for all samples. Combined with the automated microfluidic nucleic acid detection system, the system can achieve rapid detection in 30 minutes.
ISSN:1687-8760
1687-8779
DOI:10.1155/2024/4950391