Nonavailability of ultrasound: Try stethoscope in pneumatic reduction
Aim and Objective: This study aimed to finding alternative ways for centers with nonavailability of ultrasonography or fluoroscopy for nonoperative pneumatic reduction of intussusceptions. Materials and Methods: A total of 48 cases of intussusceptions were included in the study in-between October 20...
Gespeichert in:
Veröffentlicht in: | Journal of Indian Association of Pediatric Surgeons 2020-04, Vol.25 (2), p.76-79 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Aim and Objective: This study aimed to finding alternative ways for centers with nonavailability of ultrasonography or fluoroscopy for nonoperative pneumatic reduction of intussusceptions.
Materials and Methods: A total of 48 cases of intussusceptions were included in the study in-between October 2016 and March 2018. We tried stethoscope-guided pneumatic reduction using locally assembled equipment. The intraluminal pressure was monitored and maintained below 100 mmHg. A total of two attempts of 3 min each were allowed. We compared our results with the control group who have been performing laparotomy for every case of intussusception.
Results: There were 35 males and 13 females in our study. The average age of the patients was 7.5 months. Intussusceptions were reduced in 38 (80%) patients but could not be reduced in 10 (20%) patients. Majority of the intussusceptions had symptoms of at least 2 days. There were no complications such as perforation in our study.
Conclusion: Stethoscope-guided pneumatic reduction seems to be a feasible and alternative effective method for the treatment of intussusceptions in children where availability of ultrasonography and skilled radiologist with overburden of work is a great issue. |
---|---|
ISSN: | 0971-9261 1998-3891 |