Vascularised bone graft is an effective technique for extracortical bone bridging to combat cemented megaprosthesis loosening at the bone–implant junction

Introduction: The bone–implant junction is a potential site for aseptic loosening. Extracortical bone bridging at the bone–implant junction is advocated to improve implant fixation by forming a biological seal. We propose a novel technique with vascularised bone graft (VBG) to form an extracortical...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of orthopaedic surgery (Hong Kong) 2020-09, Vol.28 (3), p.2309499020958167-2309499020958167, Article 2309499020958167
Hauptverfasser: Luk, Michelle Hilda, Yee, Andy Hon-Fai, Yau, Raymond, Ho, Kenneth Wai-Yip, Lam, Ying-Lee
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction: The bone–implant junction is a potential site for aseptic loosening. Extracortical bone bridging at the bone–implant junction is advocated to improve implant fixation by forming a biological seal. We propose a novel technique with vascularised bone graft (VBG) to form an extracortical bone bridge at the bone–implant junction to enhance implant stability. We compared the clinical and radiological outcomes for tumour megaprostheses performed (1) with and without bone graft and (2) with non-vascularised versus VBG technique. Methods: Forty-six tumour megaprosthesis procedures from 1 June 2007 to 31 October 2017 were identified from hospital records. Twenty-eight operations incorporated bone graft at the bone–implant junction, and 18 did not. Of these 28 bone graft procedures, 13 involved VBG, and 15 did not (non-VBG). The VBG technique involves resecting a short segment of healthy bone beyond the oncological margin with its preserved blood supply, splitting it, then securing it over the junction. Clinical outcomes assessed included loosening, fracture and recurrence. Extracortical bone growth at the bone–implant junction was quantified radiologically at intervals 0–24 months post-operatively. The mean follow-up was 4.27 years. Results: There were five incidences (27.8%) of loosening in the non-bone graft group compared to zero in the bone graft group (p = 0.03). There was a higher radiological score of extracortical bone growth in the bone graft group compared to no bone graft at 3–24 months post-operatively (p < 0.05). Within the bone graft group, the VBG group fared superior at 6 and 12 months post-operatively compared to non-VBG (p < 0.05), as well as a lower rate of radiological junctional resorption (p = 0.04). Conclusions: We recommend bone grafting for its merits of less implant loosening. We propose the VBG technique to combat early aseptic loosening in megaprosthesis replacement as there was a higher radiological score compared to non-VBG.
ISSN:2309-4990
1022-5536
2309-4990
DOI:10.1177/2309499020958167