Detection of small changes in medical and random-dot images comparing self-organizing map performance to human detection

Radiologists use time-series of medical images to monitor the progression of a patient's conditions. They compare information gleaned from sequences of images to gain insight on progression or remission of the lesions, thus evaluating the progress of a patient's condition or response to th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Informatics in medicine unlocked 2017, Vol.7, p.39-45
Hauptverfasser: Wandeto, John Mwangi, Nyongesa, Henry, Rémond, Yves, Dresp-Langley, Birgitta
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Radiologists use time-series of medical images to monitor the progression of a patient's conditions. They compare information gleaned from sequences of images to gain insight on progression or remission of the lesions, thus evaluating the progress of a patient's condition or response to therapy. Visual methods of determining differences between one series of images to another can be subjective or fail to detect very small differences. We propose the use of quantization errors obtained from self-organizing maps (SOM) for image content analysis. We tested this technique with MRI images to which we progressively added synthetic lesions. We have used a global approach that considers changes on the entire image as opposed to changes in segmented lesion regions only. We claim that this approach does not suffer from the limitations imposed by segmentation, which may compromise the results. Results show quantization errors increased with the increase in lesions on the images. The results are also consistent with previous studies using alternative approaches. We then compared the detectability ability of our method to that of human novice observers having to detect very small local differences in random-dot images. The quantization errors of the SOM outputs compared with correct positive rates, after subtraction of false positive rates (“guess rates”), increased noticeably and consistently with small increases in local dot size that were not detectable by humans. We conclude that our method detects very small changes in complex images and suggest that it could be implemented to assist human operators in image-based decision making. •Quantization Error, a post-SOM, detects small progress/remiss of a disease condition.•Senses very small growths within image that are missed by the human expert.•Constant SOM quantifies progressive change in time.•Direct image analysis is applied to eliminate intermediate procedure bias.
ISSN:2352-9148
2352-9148
DOI:10.1016/j.imu.2017.03.001