Effect of ultrasound on Biceps femoris muscle tenderization in Nellore cattle
The effect of ultrasound on Biceps femoris muscle tenderness was investigated using a 22 Central Composite Rotatable Design (CCRD) with triplicates at the central point. We evaluated the following independent variables: ultrasound intensity ranging from 11.30 to 33.90 W cm-2 and exposure time betwee...
Gespeichert in:
Veröffentlicht in: | Ciência rural 2024, Vol.54 (2) |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The effect of ultrasound on Biceps femoris muscle tenderness was investigated using a 22 Central Composite Rotatable Design (CCRD) with triplicates at the central point. We evaluated the following independent variables: ultrasound intensity ranging from 11.30 to 33.90 W cm-2 and exposure time between 35 and 205 s. The ultrasound bath’s frequency (80 kHz) and temperature (10 ºC) were the fixed ones. To validate the model, the muscle was treated at the CCRD’s optimized condition (80 kHz, 22.60 W cm-2, 120 s, 10 ºC) evaluated, and compared with the muscle control sample (non-treated). A 22% shear force reduction was observed compared to the control sample (no ultrasound treatment) after 144 h, and stored at 5 ºC. Moreover, a sarcoplasmic calcium concentration increase was noted for ultrasound-treated muscle, probably activating the calpain enzyme system. In contrast, no significant influence (P > 0.05) was observed for pH, color index, lipid oxidation, water holding capacity, and drip loss by ultrasound treatment at the optimized conditions. Therefore, ultrasound application is promising and suitable for improving muscle tenderness without losing meat quality. This study highlighted the ultrasound effect on the tenderness of a less studied muscle (Biceps femoris) by combining short ultrasound exposure (120 s) and an 80 kHz frequency.
RESUMO: O efeito do ultrassom sob a maciez do músculo Biceps femoris foi avaliado usando um Delineamento Composto Central Rotacional (DCCR) 22 com triplicatas no ponto central. As variáveis independentes estudadas foram a intensidade do ultrassom que variou de 11,30 a 33,90 W cm-2 e o tempo de exposição de 35 e 205 s. A frequência do banho de ultrassom (80 kHz) e a temperatura (10 ºC) foram fixas. Para validar o modelo, a carne foi tratada na condição otimizada do DCCR (80 kHz, 22,60 W cm-2, 120 s, 10 ºC), avaliada e comparada à amostra controle (não tratada). Uma redução de 22% na força de cisalhamento foi observada em comparação à amostra controle após 144 h e armazenada a 5 ºC. Além disso, um aumento da concentração de cálcio sarcoplasmático foi observado para o músculo tratado com ultrassom, o que provavelmente ativou o sistema enzimático da calpaína. Em contraste, o tratamento com ultrassom nas condições otimizadas não influenciou significativamente (P > 0,05) o pH, cor, oxidação lipídica, capacidade de retenção de água e perda de gotejamento. Portanto, a aplicação do ultrassom é promissora e adequada para melhorar a maciez |
---|---|
ISSN: | 0103-8478 1678-4596 1678-4596 |
DOI: | 10.1590/0103-8478cr20220612 |