Validity of pipelle endometrial sampling in patients with abnormal uterine bleeding
We compared endometrial sampling by pipelle endometrial curette with conventional dilatation and curettage (D&C) in patients with abnormal uterine bleeding. Endometrial sampling with pipelle curette was performed on 100 patients followed by formal D&C. Samples were labeled as A and B, respec...
Gespeichert in:
Veröffentlicht in: | Annals of Saudi medicine 2008-05, Vol.28 (3), p.188-191 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We compared endometrial sampling by pipelle endometrial curette with conventional dilatation and curettage (D&C) in patients with abnormal uterine bleeding.
Endometrial sampling with pipelle curette was performed on 100 patients followed by formal D&C. Samples were labeled as A and B, respectively, and sent to a histopathologist who was blinded as to the method of sampling. The histopathology reports of both samples were compared, taking D&C as the gold standard.
An adequate sample was obtained in 98% of cases by pipelle and in 100% of cases by D&C. Pipelle had a sensitivity, specificity, positive predictive value and negative predictive value of 100% for diagnosing endometrial carcinoma, hyperplasia and secretory endometrium. Pipelle also had high diagnostic sensitivity, specificity and negative predictive value (100%, 98% and 100%, respectively) for hyperplasia with atypia, and low sensitivity (57%) and positive predictive value (57%), but high specificity (97%) and negative predictive value (97%) for endometritis. Similarly, for proliferative endometrium, the pipelle technique had values of 94% and 93% for sensitivity and specificity, respectively. Both samples labeled as inadequate for histology by pipelle were polyps on the D&C report. Difficult endotracheal intubation was encountered in two cases of D&C. No other complications of the procedure were observed.
The pipelle is a safe device for getting an adequate endometrial sample for histology, with a high sensitivity and specificity for detection of hyperplasia and malignancy. |
---|---|
ISSN: | 0256-4947 0975-4466 |
DOI: | 10.4103/0256-4947.51721 |