Calculation of the Combined Heat Transfer Coefficient of Hot-face on Cast Iron Cooling Stave Based on Thermal Test

Cooling effects of the cast iron cooling stave were tested with a specially designed experimental furnace under the conditions of different temperatures of 800 °C, 900 °C, 1,000 °C and 1,100 °C as well as different cooling water velocities of 0.5 m·s , 1.0 m·s , 1.5 m·s and 2.0 m·s . Furthermore, th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:High temperature materials and processes 2017-03, Vol.36 (3), p.249-256
Hauptverfasser: Li, Feng-guang, Zhang, Jian-liang, Zuo, Hai-bin, Qin, Xuan, Qi, Cheng-lin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Cooling effects of the cast iron cooling stave were tested with a specially designed experimental furnace under the conditions of different temperatures of 800 °C, 900 °C, 1,000 °C and 1,100 °C as well as different cooling water velocities of 0.5 m·s , 1.0 m·s , 1.5 m·s and 2.0 m·s . Furthermore, the combined heat transfer coefficient of hot-face on cast iron cooling stave ( ) was calculated by heat transfer theory based on the thermal test. The calculated was then applied in temperature field simulation of cooling stave and the simulation results were compared with the experimental data. The calculation of indicates that increases rapidly as the furnace temperature increases while it increases a little as the water velocity increases. The comparison of the simulation results with the experimental data shows that the simulation results fit well with the experiment data under different furnace temperatures.
ISSN:0334-6455
2191-0324
DOI:10.1515/htmp-2015-0212