Determination of diclofenac in pharmaceutical preparations by voltammetry and gas chromatography methods

Rapid, sensitive and specific methods were developed for the determination of diclofenac in pharmaceutical preparations by linear sweep voltammetry (LSV) and gas chromatography (GC) with mass spectrometry (MS) detection. The linearity was established over the concentration range of 5- 35 μg/mL for L...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical analysis 2015-06, Vol.5 (3), p.153-160
Hauptverfasser: Yilmaz, Bilal, Ciltas, Ulvihan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Rapid, sensitive and specific methods were developed for the determination of diclofenac in pharmaceutical preparations by linear sweep voltammetry (LSV) and gas chromatography (GC) with mass spectrometry (MS) detection. The linearity was established over the concentration range of 5- 35 μg/mL for LSV and 0.25-5 μg/mL for GC-MS method. The intra- and inter-day relative standard deviation (RSD) was less than 4.39% and 4.62% for LSV and GC-MS, respectively. Limits of quantification (LOQ) were determined as 4.8 and 0.15 μg/mL for LSV and GC-MS, respectively. No interference was found from tablet excipients at the selected assay conditions. The methods were applied for the quality control of commercial diclofenac dosage forms to quantify the drug and to check the formulation content uniformity.
ISSN:2095-1779
2214-0883
DOI:10.1016/j.jpha.2014.10.005