Novel Burst-Mode Control for Medium-to-Light Load Operation of Dual-Active-Bridge Converters, Achieving Minimum Backflow Power, Zero-Voltage-Switching, and DC Bias Suppression
The dual-active-bridge (DAB) converter is widely used in many applications such as solid-state transformers, multi-port converters, and on-board chargers. Nevertheless, its efficiency degrades significantly under light-load conditions due to high switching and conduction losses. Since a detailed ana...
Gespeichert in:
Veröffentlicht in: | Energies (Basel) 2024-11, Vol.17 (22), p.5748 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The dual-active-bridge (DAB) converter is widely used in many applications such as solid-state transformers, multi-port converters, and on-board chargers. Nevertheless, its efficiency degrades significantly under light-load conditions due to high switching and conduction losses. Since a detailed analysis for burst-mode design has not been presented in the literature, effective burst-mode control for the light-load condition is proposed in this paper. In the proposed burst-mode, the regular duty cycle and the burst duty cycle are optimally coordinated to achieve the zero-voltage-switching (ZVS) condition and the minimum backflow power at the same time. Moreover, DC bias current is effectively eliminated in the proposed burst-mode. The switching loss and conduction loss are simultaneously minimized in the proposed burst-mode control. Therefore, the light-load efficiency is significantly improved. The detailed analysis and design procedure are also presented for both buck- and boost-mode operations to deal with widely varying output voltage ranges. The control mode switching condition is determined for achieving the ZVS condition for the whole load condition; thus, the proposed burst-mode control flowchart is presented. A 4 kW DAB converter prototype is built to verify the proposed method and the experiment results show about a 2% increment in efficiency of the proposed method compared to the conventional burst-mode method. |
---|---|
ISSN: | 1996-1073 1996-1073 |