Mask R-CNN provides efficient and accurate measurement of chondrocyte viability in the label-free assessment of articular cartilage
Chondrocyte viability (CV) can be measured with the label-free method using second harmonic generation (SHG) and two-photon excitation autofluorescence (TPAF) imaging. To automate the image processing for the label-free CV measurement, we previously demonstrated a two-step deep-learning method: Step...
Gespeichert in:
Veröffentlicht in: | Osteoarthritis and cartilage open 2023-12, Vol.5 (4), p.100415-100415, Article 100415 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Chondrocyte viability (CV) can be measured with the label-free method using second harmonic generation (SHG) and two-photon excitation autofluorescence (TPAF) imaging. To automate the image processing for the label-free CV measurement, we previously demonstrated a two-step deep-learning method: Step 1 used a U-Net to segment the lacuna area on SHG images; Step 2 used dual CNN networks to count live cells and the total number of cells in extracted cell clusters from TPAF images. This study aims to develop one-step deep learning methods to improve the efficiency of CV measurement.
TPAF/SHG images were acquired simultaneously on cartilage samples from rats and pigs using two-photon microscopes and were merged to form RGB color images with red, green, and blue channels assigned to emission bands of oxidized flavoproteins, reduced forms of nicotinamide adenine dinucleotide, and SHG signals, respectively. Based on the Mask R-CNN, we designed a deep learning network and its denoising version using Wiener deconvolution for CV measurement.
Using training and test datasets from rat and porcine cartilage, we have demonstrated that Mask R-CNN-based networks can segment and classify individual cells with a single-step processing flow. The absolute error (difference between the measured and the ground-truth CV) of the CV measurement using the Mask R-CNN with or without Wiener deconvolution denoising reaches 0.01 or 0.08, respectively; the error of the previous CV networks is 0.18, significantly larger than that of the Mask R-CNN methods.
Mask R-CNN-based deep-learning networks improve efficiency and accuracy of the label-free CV measurement. |
---|---|
ISSN: | 2665-9131 2665-9131 |
DOI: | 10.1016/j.ocarto.2023.100415 |