Extubation from high-frequency oscillatory ventilation in extremely low birth weight infants: a prospective observational study

ObjectiveTo evaluate if weaning from high-frequency oscillatory ventilation (HFOV) directly to a non-invasive mode of respiratory support is feasible and results in successful extubation in extremely low birth weight (ELBW) infants.DesignProspective observational study.SettingTertiary neonatal inten...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMJ paediatrics open 2018-11, Vol.2 (1), p.e000350-e000350
Hauptverfasser: Tana, Milena, Lio, Alessandra, Tirone, Chiara, Aurilia, Claudia, Tiberi, Eloisa, Serrao, Francesca, Purcaro, Velia, Corsello, Mirta, Catenazzi, Piero, D’Andrea, Vito, Barone, Giovanni, Ricci, Cinzia, Pastorino, Roberta, Vento, Giovanni
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:ObjectiveTo evaluate if weaning from high-frequency oscillatory ventilation (HFOV) directly to a non-invasive mode of respiratory support is feasible and results in successful extubation in extremely low birth weight (ELBW) infants.DesignProspective observational study.SettingTertiary neonatal intensive care unit.PatientsOne hundred and eight ELBW infants of 26.2±1.4 weeks of gestational age (GA) directly extubated from HFOV.InterventionsAll infants were managed with elective HFOV and received surfactant after a recruitment HFOV manoeuvre. Extubation was attempted at mean airways pressure (MAP) ≤6 cm H2O with FiO2 ≤0.25. After extubation, all infants were supported by nasal continuous positive airway pressure (6–8 cm H2O).Main outcome measuresExtubation failure (clinical deterioration requiring reintubation) was defined as shorter than 7 days.ResultsNinety patients (83%) were successfully extubated and 18 (17%) required reintubation. No significant differences were found between the two groups in terms of birth weight, day of life and weight at the time of extubation. Multivariable analysis showed that GA (OR 1.71; 95% CI 1.04, 2.08) and higher MAP prior to surfactant (OR 1.51; 95% CI 1.06, 2.15) were associated with successful extubation.ConclusionsIn ELBW infants, direct extubation from HFOV at MAP ≤6 cm H2O with FiO2 ≤0.25 is feasible. Our extubation success rate (83%) is higher than conventional mechanical ventilation in this very vulnerable class of infants.
ISSN:2399-9772
2399-9772
DOI:10.1136/bmjpo-2018-000350