Liver Graft Failure after Plastic Stent Removal of an Anastomotic Biliary Stricture

A biliary anastomotic stricture developed 13 months after living donor liver transplantation in a 19-year-old male with congenital hepatic fibrosis. Endoscopic management with balloon dilation followed by the placement of a 7F plastic stent was performed for the anastomotic stricture. After 6 months...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Korean journal of gastroenterology 2022-05, Vol.79 (5), p.217-221
Hauptverfasser: Chun, Jung Won, Yi, Nam-Joon, Kim, Haeryoung, Paik, Woo Hyun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A biliary anastomotic stricture developed 13 months after living donor liver transplantation in a 19-year-old male with congenital hepatic fibrosis. Endoscopic management with balloon dilation followed by the placement of a 7F plastic stent was performed for the anastomotic stricture. After 6 months of indwelling of the stent, the plastic stent was removed because the stenosis and cholestasis were improved. One month after stent removal, he was admitted for acute liver graft failure owing to cholestatic hepatitis, and required retransplantation secondary to graft loss.
ISSN:1598-9992
2233-6869