Evaluación del riesgo en la salud del personal del Parque Nacional Volcán Poás, Costa Rica, por exposición a los gases SO2 y H2S

[Objective] Verify the levels of exposure to SO2 and H2S of park rangers at the Poás Volcano National Park, using OSHA international standards as a reference. [Methodology] SO2 and H2S concentrations were studied from September 2018 to December 2019 and February 2019 to December 2019, respectively u...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Uniciencia 2024-12, Vol.38 (1), p.1-16
Hauptverfasser: Morales-Alpízar, José David, Sibaja-Brenes, José Pablo, Mora-Barrantes, José Carlos, Martínez-Cruz, María, Borbón-Alpízar, Henry, Retana-Díaz, Alexa, Alfaro-Solís, Rosa
Format: Artikel
Sprache:por ; spa
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Objective] Verify the levels of exposure to SO2 and H2S of park rangers at the Poás Volcano National Park, using OSHA international standards as a reference. [Methodology] SO2 and H2S concentrations were studied from September 2018 to December 2019 and February 2019 to December 2019, respectively using MultiRae portable detection equipment. Sampling points were placed at the ranger’s house, the entrance station, the visitors' center, and the overlook. The level of chemical risk was determined taking into consideration: the workers’ health, exposure time, safety equipment, training, and TWA and STEL values obtained. [Results] The highest SO2 concentration was 16.0 ppm, which was recorded at the visitor center, while the highest H2S concentration was 45 ppm, which was obtained from the park ranger’s house. The average gas concentration was close to the detection limit for both gasses, suggesting that gasses, in general, are not directed toward visitors’ areas. No measurement station exceeded 2 ppm for SO2 in 8 hours (TWA). However, in the visitors’ center and the overlook, SO2 exceeded 5 ppm in 15 minutes (STEL) with concentrations equal to 10.1 ppm and 7.4 ppm, respectively. [Conclusions] Low levels of chemical hazard were obtained for both gasses at the sampling points, except for the visitors’ center which had a medium level. [Objetivo] Verificar el cumplimiento de los niveles de exposición a SO2 y H2S, de los guardaparques del Parque Nacional Volcán Poás, tomando como referencia la norma internacional OSHA. [Metodología] Se estudió la concentración del SO2 desde setiembre 2018, hasta diciembre 2019 y para el H2S de febrero 2019, hasta diciembre 2019, haciendo uso de equipos de detección portátiles MultiRae. Los puntos de muestreo se colocaron en la casa de guardaparques, la caseta de entrada, el centro de visitantes y el mirador. El nivel de riesgo químico se determinó considerando: la salud de los trabajadores, el tiempo de exposición, el equipo de seguridad, las capacitaciones y los valores de TWA y STEL obtenidos. [Resultados] El valor más alto de la concentración de SO2 fue de 16,0 ppm, se registró en el centro de visitantes, y para el de H2S fue de 45 ppm (casa de guardaparques). La concentración promedio de los gases estuvo cercana al límite de detección para ambos gases, sugiriendo que los gases, en general, no se dirigen hacia las zonas de visitación. Ningún puesto de medición superó los 2 ppm para el SO2 en 8 horas (TWA). Sin embargo, en el cen
ISSN:2215-3470
2215-3470
DOI:10.15359/ru.38-1.28