Effect of in-office bleaching agent on the surface roughness and microhardness of nanofilled and nanohybrid composite resins [version 2; peer review: 2 approved]
Background: To compare the surface roughness and microhardness of Ceram.x® SphereTEC™ one and Filtek Z350 XT after in-office bleaching with Pola office. Methods: Twenty samples each of (10 mm diameter and 2 mm height) Ceram.x® SphereTEC™ one and Filtek Z350 XT were prepared. The samples were subject...
Gespeichert in:
Veröffentlicht in: | F1000 research 2023, Vol.12, p.129-129 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: To compare the surface roughness and microhardness of Ceram.x® SphereTEC™ one and Filtek Z350 XT after in-office bleaching with Pola office.
Methods: Twenty samples each of (10 mm diameter and 2 mm height) Ceram.x® SphereTEC™ one and Filtek Z350 XT were prepared. The samples were subjected to three bleaching sessions with 35% hydrogen peroxide (Pola office) with a seven-day interval between each session. Surface roughness and microhardness of the prepared samples prior to and after the bleaching regimen were measured using a profilometer and Vickers hardness tester, respectively.
Results: A significant reduction (p |
---|---|
ISSN: | 2046-1402 2046-1402 |