Reliable smart models for estimating frictional pressure drop in two-phase condensation through smooth channels of varying sizes

Reliable and comprehensive predictive tools for the frictional pressure drop (FPD) are of particular importance for systems involving two-phase flow condensation. However, the available models are only applicable to specific operating conditions and channel sizes. Thus, this study aims at developing...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scientific reports 2024-05, Vol.14 (1), p.10515-10515, Article 10515
Hauptverfasser: Moradkhani, M. A., Hosseini, S. H., Song, Mengjie, Abbaszadeh, A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Reliable and comprehensive predictive tools for the frictional pressure drop (FPD) are of particular importance for systems involving two-phase flow condensation. However, the available models are only applicable to specific operating conditions and channel sizes. Thus, this study aims at developing universal models to estimate the FPD during condensation inside smooth mini/micro and conventional (macro) channels. An extensive databank, comprising 8037 experimental samples and 23 working fluids from 50 reliable sources, was prepared to achieve this target. A comprehensive investigation on the literature models reflected the fact that all of them are associated with high deviations, and their average absolute relative errors (AAREs) exceed 26%. Hence, after identifying the most effective input variables through the Spearman's correlation analysis, three soft-computing paradigms, i.e., multilayer perceptron (MLP), gaussian process regression (GPR) and radial basis function (RBF) were employed to establish intelligent and dimensionless predictive tools for the FPD based on the separated model suggested by Lockhart and Martinelli. Among them, the most accurate results were presented by the GPR approach with AARE and R 2 values of 4.10%, 99.23% respectively, in the testing step. The truthfulness and applicability of the models were explored through an array of statistical and visual analyses, and the results affirmed the obvious superiority of the newly proposed approaches over the literature correlations. Furthermore, the novel predictive tools excellently described the physical variations of the condensation FPD versus the operating parameters. Ultimately, the order of importance of factors in controlling the condensation FPD was clarified by a sensitivity analysis.
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-024-60898-7