Realization and research of self-healing technology of power communication equipment based on power safety and controllability

The reliability of power communication networks is vital to ensure uninterrupted operation in power electronics. Self-healing techniques address this need by automating fault identification and recovery. However, existing methods struggle with dynamic challenges like voltage fluctuations, thermal ov...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy Informatics 2025-12, Vol.8 (1), p.1-18, Article 1
Hauptverfasser: Liu, Danni, Zhang, Song, Wang, Shengda, Zhou, Mingwei, Du, Ji
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The reliability of power communication networks is vital to ensure uninterrupted operation in power electronics. Self-healing techniques address this need by automating fault identification and recovery. However, existing methods struggle with dynamic challenges like voltage fluctuations, thermal overloads, and multidimensional sensor data, often leading to delays in fault recovery and reduced safety. This study aims to develop the Self Heal Power Safe Predictor (SHPSP) model to overcome the limitations of prior self-healing techniques. The primary objectives include improving fault prediction accuracy, enhancing recovery speed, and ensuring resilience under diverse and high-stress operational conditions. The SHPSP model employs an ensemble-based classification strategy within a majority voting framework, focusing on multidimensional sensor data such as voltage, temperature, and safety indicators. Feature selection is optimized using ensembled filter and wrapper techniques to prioritize critical parameters. The model is validated against conventional methods using metrics like accuracy, precision, recall, F1-score, and MCC. Experimental results demonstrate that the SHPSP model significantly outperforms previous approaches, achieving higher fault detection accuracy and faster recovery, particularly during voltage drops, power surges, and thermal stress. The SHPSP classifier obtained 91.4% accuracy, 88.2% precision, 89.5% recall, 89.8% F1-score, 81.0% MCC, and a 92.0% ROC-AUC curve. The SHPSP model ensures enhanced safety, dependability, and robustness for power electronics systems, marking a significant advancement in self-healing technology.
ISSN:2520-8942
2520-8942
DOI:10.1186/s42162-024-00460-x