Experimental Investigation on the Rehabilitation of RC Flat Slabs Using CFRP Sheets to Enhance Punching Shear Capacity

In this paper, the feasibility of strengthening a flat column–slab connection within the carbon fiber reinforced polymer (CFRP) has been investigated through experimental study. The experimental program includes a set of nine reinforced concrete flat slab specimens. Three unaltered specimens served...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Buildings (Basel) 2024-01, Vol.14 (1), p.153
Hauptverfasser: Abdul Sahib, Mohammed Qusay, Aghayari, Reza, Moradi, Mohammad Javad, Tahamouli Roudsari, Mehrzad
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, the feasibility of strengthening a flat column–slab connection within the carbon fiber reinforced polymer (CFRP) has been investigated through experimental study. The experimental program includes a set of nine reinforced concrete flat slab specimens. Three unaltered specimens served as control slabs, while an additional six samples were strengthened with various CFRP configurations to enhance their shear capacity. The strain distribution, ductility, punching shear resistance, stiffness, and crack formation were studied. The result of experimental studies showed that in the direct method of strengthening in which two layers of unidirectional CFRP sheets were employed in two opposite directions, the ultimate punching shear resistance improved by 64%, 44.7%, and 15.3%, with respect to the location of the column connection, as compared with the control specimens. In the case of using one layer of unidirectional CFRP strips, the punching shear resistance was enhanced by approximately 16% and 39%, considering the configuration of CFRP sheets and the amount of strengthened and adhesive layers used. Following the outcomes of this research, the application of CFRPs in improving the resistance capacity of flat slabs against the punching shear is considerable. The reported outcomes were compared with the latest provisions of ACI to show the efficiency of the presented strengthening. Finally, a parametric study was performed assuming different loading locations to assess the effect of the loading region on the response of RC slabs. Results indicate that approaching the loading location toward the RC slab supports results of an increase in the load-bearing capacity and a reduction in the ductility of the RC slab.
ISSN:2075-5309
2075-5309
DOI:10.3390/buildings14010153