Standardised electronic algorithms for monitoring prophylaxis of postoperative nausea and vomiting

Despite comprehensive guidelines with high-grade evidence, postoperative nausea and vomiting (PONV) remains a frequent problem in anaesthesia care. Anaesthesia information management systems (AIMS) may aid clinicians in PONV prevention, but their benefit is critically dependent on the details of imp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of medical science 2019-03, Vol.15 (2), p.408-415
Hauptverfasser: Gillmann, Hans-Jörg, Wasilenko, Sascha, Züger, Jonathan, Petersen, Antje, Klemann, Anna, Leffler, Andreas, Stueber, Thomas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Despite comprehensive guidelines with high-grade evidence, postoperative nausea and vomiting (PONV) remains a frequent problem in anaesthesia care. Anaesthesia information management systems (AIMS) may aid clinicians in PONV prevention, but their benefit is critically dependent on the details of implementation into practice. This study aimed to examine strengths and weaknesses of the local AIMS-based algorithm in prevention of PONV. This retrospective study was conducted in the post-anaesthesia care unit (PACU) of a university hospital and included 10 604 patients aged 18 or older who were followed up in the PACU (intracranial, obstetrical or cardiothoracic surgery excluded) from March 2013 until March 2014. The PONV incidence in PACU and AIMS data validity were analysed. Adherence to PONV guideline recommendations was considerably low, with only 5749 (54%) of the patients receiving correct PONV prophylaxis. Two thousand seven hundred sixty-six (26%) of the patients received an insufficient PONV prophylaxis, which was associated with an excess PONV incidence (11% vs. 4% with correct prophylaxis, < 0.001) in the PACU. Two thousand four hundred forty-nine (23%) of all patients were discharged from the PACU with an insufficient PONV prophylaxis despite perioperative digital PONV prevention algorithms. Adherence to PONV prophylaxis guidelines in the era of AIMS software and decision support is still remarkably low. The AIMS data usefulness depends on the user, the type of data input and the configuration of the software. Adherence to correct PONV prophylaxis should be re-evaluated systematically before discharge from PACU.
ISSN:1734-1922
1896-9151
DOI:10.5114/aoms.2019.83293