Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring
To describe a new technique for transconjunctival intrascleral fixation of Cionni CTR using double-flanged polypropylens suture. This is a prospective interventional case series which included 7 cases with severe (more than 180 degrees) zonular dialysis. Three cases were hereditary lens subluxation...
Gespeichert in:
Veröffentlicht in: | Clinical ophthalmology (Auckland, N.Z.) N.Z.), 2020-01, Vol.14, p.1055-1058 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To describe a new technique for transconjunctival intrascleral fixation of Cionni CTR using double-flanged polypropylens suture.
This is a prospective interventional case series which included 7 cases with severe (more than 180 degrees) zonular dialysis. Three cases were hereditary lens subluxation (Marfan syndrome), 2 cases with traumatic subluxation and 2 cases with pseudo-exfoliation syndrome.
All cases achieved a good postoperative stable and centered IOL with good visual results. No postoperative complications were recorded apart from PCO in 3 cases and mild bleeding during needle passage in one case.
This described technique is a simple, time sparing and minimally invasive method for achieving good bag centration. It eliminates the need of conjunctival peritomy, subconjunctival vessels cautery and scleral fashioning of a flap, pocket or a groove. The use of 6/0 polypropylene theoretically can achieve better longevity. |
---|---|
ISSN: | 1177-5467 1177-5483 1177-5483 |
DOI: | 10.2147/OPTH.S244751 |