Reliability and Validity of the Japanese Version of the Basel Assessment of Adherence to Immunosuppressive Medications Scale in Kidney Transplant Recipients

A valid and reliable instrument that can measure adherence is needed to identify nonadherent patients and to improve adherence. However, there is no validated Japanese self-report instrument to evaluate adherence to immunosuppressive medications for transplant patients. The purpose of this study was...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Transplantation direct 2023-02, Vol.9 (3), p.e1457-e1457
Hauptverfasser: Kosoku, Akihiro, Iwai, Tomoaki, Masuda, Hiroo, Kabei, Kazuya, Nishide, Shunji, Maeda, Keiko, Yoshikawa, Yuki, Nakamura, Yasutaka, De Geest, Sabina, Uchida, Junji
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A valid and reliable instrument that can measure adherence is needed to identify nonadherent patients and to improve adherence. However, there is no validated Japanese self-report instrument to evaluate adherence to immunosuppressive medications for transplant patients. The purpose of this study was to determine the reliability and validity of the Japanese version of the Basel Assessment of Adherence to Immunosuppressive Medications Scale (BAASIS). We translated the BAASIS into Japanese and developed the Japanese version of the BAASIS (J-BAASIS) according to the International Society of Pharmacoeconomics and Outcomes Research task force guidelines. We analyzed the reliability (test-retest reliability and measurement error) and validity of the J-BAASIS (concurrent validity with the medication event monitoring system and the 12-item Medication Adherence Scale) referring to the COSMIN Risk of Bias checklist. A total of 106 kidney transplant recipients were included in this study. In the analysis of test-retest reliability, Cohen's kappa coefficient was found to be 0.62. In the analysis of measurement error, the positive and negative agreement were 0.78 and 0.84, respectively. In the analysis of concurrent validity with the medication event monitoring system, sensitivity and specificity were 0.84 and 0.90, respectively. In the analysis of concurrent validity with the 12-item Medication Adherence Scale, the point-biserial correlation coefficient for the "medication compliance" subscale was 0.38 (  
ISSN:2373-8731
2373-8731
DOI:10.1097/TXD.0000000000001457