Comparison of Numerically Simulated and Measured Dose Rates for Gamma-Irradiation Facility

The article provides a description of steps which were made to make comparison between numerically simulated and measured dose rates in Izotop gamma-irradiation facility (Budapest, Hungary) Numerical simulation was carried out with the help of software toolkit GEANT4. Dose measurement were made by e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:East European journal of physics 2022-06 (2), p.118-123
Hauptverfasser: Morgunov, Volodymyr, Madar, Imre, Lytovchenko, Serhii, Chyshkala, Volodymyr, Mazilin, Bohdan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The article provides a description of steps which were made to make comparison between numerically simulated and measured dose rates in Izotop gamma-irradiation facility (Budapest, Hungary) Numerical simulation was carried out with the help of software toolkit GEANT4. Dose measurement were made by ethanol-chlorobenzene (ECB) dosimeters. The comparison shows a good agreement between simulated and measured values. Worst accuracy was 17.08%.
ISSN:2312-4334
2312-4539