Appropriate patient instructions can reduce prostate motion

Interfraction prostate motion must be compensated by increased safety margins. If filling status of rectum and bladder is constant, motion should be reduced. We attempted to reduce interfraction motion errors by proper patient instruction. In 38 patients pairs of radio-opaque fiducial markers were i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation oncology (London, England) England), 2012-08, Vol.7 (1), p.125-125, Article 125
Hauptverfasser: Graf, Reinhold, Boehmer, Dirk, Nadobny, Jacek, Budach, Volker, Wust, Peter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Interfraction prostate motion must be compensated by increased safety margins. If filling status of rectum and bladder is constant, motion should be reduced. We attempted to reduce interfraction motion errors by proper patient instruction. In 38 patients pairs of radio-opaque fiducial markers were implanted prior to definitive radiotherapy. Patients were positioned either according to skin marks or infrared body marker. We measured prostate displacement, i.e. pelvic bones versus intraprostatic marker position, via ExacTrac (two orthogonal radiographies) in 1252 fractions. Systematic and random setup and displacement errors were determined and safety margins estimated. In our study interfraction prostate displacement is 
ISSN:1748-717X
1748-717X
DOI:10.1186/1748-717x-7-125