Sutureless Intrascleral Posterior Chamber Intraocular Lens Fixation: Analysis of Clinical Outcomes and Postoperative Complications

Purpose. To report a technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (PC-IOL) and analyzing the clinical outcomes and postoperative complications. Study Design. 68 eyes of 66 patients who received the technique were studied retrospectively. Methods....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of ophthalmology 2021, Vol.2021, p.8857715-7
Hauptverfasser: Liu, Jiannan, Fan, Wenxue, Lu, Xinyu, Peng, Shaomin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose. To report a technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (PC-IOL) and analyzing the clinical outcomes and postoperative complications. Study Design. 68 eyes of 66 patients who received the technique were studied retrospectively. Methods. The best-corrected visual acuity (BCVA), intraocular pressure (IOP), anterior chamber depth (ACD), IOL tilt and decentration, corneal topography (K1 and K2), and postoperative complications were determined at 3 months. Results. The mean preoperative BCVA was 1.63 ± 1.24 logMAR units, and the mean postoperative BCVA was 0.74 ± 0.59 logMAR units at 3 months (P
ISSN:2090-004X
2090-0058
DOI:10.1155/2021/8857715