Thoracic fluid content: a novel parameter for predicting failed weaning from mechanical ventilation
Weaning of patients from the mechanical ventilation remains one of the critical decisions in intensive care unit. This study aimed to evaluate the accuracy of thoracic fluid content (TFC) as a predictor of weaning outcome. An observational cohort study included 64 critically ill surgical patients wh...
Gespeichert in:
Veröffentlicht in: | Journal of intensive care 2020-03, Vol.8 (1), p.20-20, Article 20 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Weaning of patients from the mechanical ventilation remains one of the critical decisions in intensive care unit. This study aimed to evaluate the accuracy of thoracic fluid content (TFC) as a predictor of weaning outcome.
An observational cohort study included 64 critically ill surgical patients who were eligible for extubation. Before initiating the spontaneous breathing trial, the TFC was measured using the electrical cardiometry technology. Patients were followed up after extubation and divided into successful weaning group and failed weaning group. Both groups were compared according to respiratory and cardiovascular parameters. Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of TFC to predict weaning outcome.
The number of successfully weaned patients was 41/64 (64%). Twenty (31%) patients had impaired cardiac contractility, and of them, 13/20 (64%) patients were successfully extubated. Both groups, successful weaning group and failed weaning group, were comparable in most of baseline characteristics; however, the TFC was significantly higher in the failed weaning group compared to the successful weaning group. The area under the ROC curves (AUCs) showed moderate predictive ability for the TFC in predicting weaning failure (AUC [95% confidence interval] 0.69 [0.57-0.8], cutoff value > 50 kΩ
), while the predictive ability of TFC was excellent in the subgroup of patients with ejection fraction < 40% (AUC [95% confidence interval 0.93 [0.72-1], cutoff value > 50 kΩ
).
Thoracic fluid content showed moderate ability for predicting weaning outcome in surgical critically ill patients. However, in the subgroup of patients with ejection fraction less than 40%, TFC above 50 kΩ
has an excellent ability to predict weaning failure. |
---|---|
ISSN: | 2052-0492 2052-0492 |
DOI: | 10.1186/s40560-020-00439-2 |