Sulfur Poisoning and Performance Recovery of SOFC Air Electrodes
The sulfur poisoning and performance recovery of the state-of-the-art SOFC cathodes (La 0 . 80 Sr 0 . 20 ) 0 . 95 MnO 3 ± δ (LSM) and (La 0 . 60 Sr 0 . 40 ) 0 . 95 Co 0 . 20 Fe 0 . 80 O 3 – δ (LSCF), have been studied. Electrochemical impedance spectroscopy measurements of LSCF|GDC and LSM|YSZ half-...
Gespeichert in:
Veröffentlicht in: | Frontiers in energy research 2021-04, Vol.9 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The sulfur poisoning and performance recovery of the state-of-the-art SOFC cathodes (La
0
.
80
Sr
0
.
20
)
0
.
95
MnO
3
±
δ
(LSM) and (La
0
.
60
Sr
0
.
40
)
0
.
95
Co
0
.
20
Fe
0
.
80
O
3
–
δ
(LSCF), have been studied. Electrochemical impedance spectroscopy measurements of LSCF|GDC and LSM|YSZ half-cells are carried out in alternating atmospheres of air and SO
2
–air at 700°C for hundreds of hours. In the presence of SO
2
, the electrochemical performance of both the cells decays with ohmic and non-ohmic losses, owing to the absorption and chemical interaction of SO
2
with the electrodes. In LSCF, the SrO segregated on the surface tends to absorb and react with SO
2
, forming SrSO
4
followed by the exsolution of Co-Fe. As for LSM, SO
2
is absorbed onto the Sr-rich areas of LSM, including the active reaction sites near the TPBs, leading to Sr exsolution and SrSO
4
formation, leaving a Sr-deficient LSM. During the subsequent exposure to air, the performance of the sulfur-contaminated LSM is almost restored. The LSM particles, exposed to alternating atmospheres of air and SO
2
-air during the electrochemical tests, show a relatively clean surface with sparsely distributed SrSO
4
particles, indicating a high stability against sulfur poisoning. It is suggested that the loosely adsorbed SO
2
at the TPBs is readily swept away by the SO
2
-free air flow, recovering its ORR activity, whereas the Sr-deficient LSM due to Sr-exsolution stays modified, contributing to the incomplete performance restoration. Unlike the case of LSM, the performance of the sulfur-poisoned LSCF partially recovers during the subsequent exposure to air. Correspondingly, the LSCF particles have a modified morphology covered with numerous nanoparticles, mostly SrSO
4
, showing the irreversible aspect of the sulfur poisoning. The morphology modification is not concentrated near the electrode/electrolyte interface but over the entire cathode, indicating that the degree of recovery from sulfur poisoning is closely related to the presence of SrO and chemical activity of Sr in the electrodes at the solid-gas interface. These results also show the potential application of LSM for a sulfur sensor available in high-temperature harsh conditions. |
---|---|
ISSN: | 2296-598X 2296-598X |
DOI: | 10.3389/fenrg.2021.643431 |