Testing proposed quality measures for treatment of carpal tunnel syndrome: feasibility, magnitude of quality gaps, and reliability

The American Academy of Orthopaedic Surgeons and American Society for Surgery of the Hand recently proposed three quality measures for carpal tunnel syndrome (CTS): Measure 1 - Discouraging routine use of Magnetic resonance imaging (MRI) for diagnosis of CTS; Measure 2 - Discouraging the use of adju...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMC health services research 2020-09, Vol.20 (1), p.861-861, Article 861
Hauptverfasser: Harris, Alex H S, Meerwijk, Esther L, Ding, Qian, Trickey, Amber W, Finlay, Andrea K, Schmidt, Eric M, Curtin, Catherine M, Sears, Erika D, Nuckols, Teryl K, Kamal, Robin N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The American Academy of Orthopaedic Surgeons and American Society for Surgery of the Hand recently proposed three quality measures for carpal tunnel syndrome (CTS): Measure 1 - Discouraging routine use of Magnetic resonance imaging (MRI) for diagnosis of CTS; Measure 2 - Discouraging the use of adjunctive surgical procedures during carpal tunnel release (CTR); and Measure 3 - Discouraging the routine use of occupational and/or physical therapy after CTR. The goal of this study were to 1) Assess the feasibility of using the specifications to calculate the measures in real-world healthcare data and identify aspects of the specifications that might be clarified or improved; 2) Determine if the measures identify important variation in treatment quality that justifies expending resources for their further development and implementation; 3) Assess the facility- and surgeon-level reliability of measures. The measures were calculated using national data from the Veterans Health Administration (VA) Corporate Data Warehouse for three fiscal years (FY; 2016-18). Facility- and surgeon-level performance and reliability were examined. To expand the testing context, the measures were also tested using data from an academic medical center. The denominator of Measure 1 was 132,049 VA patients newly diagnosed with CTS. The denominators of Measures 2 and 3 were 20,813 CTRs received by VA patients. The median facility-level performances on the three measures were 96.5, 100, and 94.7%, respectively. Of 130 VA facilities, none had
ISSN:1472-6963
1472-6963
DOI:10.1186/s12913-020-05704-6