Comparison of haemodynamic responses to intubation: Flexible fibreoptic bronchoscope versus bonfils rigid intubation endoscope
The flexible fibreoptic bronchoscope and bonfils rigid intubation endoscope are being widely used for difficult intubations. The haemodynamic response to intubation under general anaesthesia was studied in 60 adult female patients who were intubated using either flexible fibreoptic bronchoscope or b...
Gespeichert in:
Veröffentlicht in: | Indian journal of anaesthesia 2012-07, Vol.56 (4), p.353-358 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The flexible fibreoptic bronchoscope and bonfils rigid intubation endoscope are being widely used for difficult intubations.
The haemodynamic response to intubation under general anaesthesia was studied in 60 adult female patients who were intubated using either flexible fibreoptic bronchoscope or bonfils rigid intubation endoscope (30 in each group). Non-invasive blood pressure and heart rate (HR) was recorded before induction of anaesthesia, immediately after induction, at the time of intubation and, thereafter, every minute for the next 5 min. The product of HR and systolic blood pressure (rate pressure product) at every point of time was also calculated.
Graph pad prism, 5.0 statistical software, independent t test and repeated measure ANOVA test were used.
Both bonfils rigid intubation endoscope and flexible fibreoptic bronchoscope required a similar time (less than 1 min) for orotracheal intubation. After intubation, there was a significant increase in HR, blood pressure and rate pressure product (P |
---|---|
ISSN: | 0019-5049 0976-2817 |
DOI: | 10.4103/0019-5049.100816 |