Embolization of the false lumen using IMPEDE-FX embolization plugs as part of treatment of an infrarenal post-dissection aneurysm: a case report

Background This case report demonstrates the value of IMPEDE-FX plugs in an embolization procedure of a false lumen of an infrarenal post-dissection aneurysm. Case presentation A 69-year-old patient was treated with mitral valve replacement, complicated by a Stanford type-A dissection. After 9 years...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:CVIR endovascular 2020-12, Vol.3 (1), p.91-91, Article 91
Hauptverfasser: Jansen, Anne-Jet S., van Schaik, Paul M., Martens, Jasper M., Reijnen, Michel M. P. J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background This case report demonstrates the value of IMPEDE-FX plugs in an embolization procedure of a false lumen of an infrarenal post-dissection aneurysm. Case presentation A 69-year-old patient was treated with mitral valve replacement, complicated by a Stanford type-A dissection. After 9 years he presented with an enlarging infrarenal post-dissection aneurysm. The false lumen was embolized using multiple IMPEDE-FX plugs as part of the treatment in addition to embolization of the inferior mesenteric artery and overstenting of the re-entry in the right iliac artery. At 15 months the CTA showed a fully thrombosed false lumen and remodeling of the true lumen. Conclusions The false lumen of an infrarenal post-dissection aneurysm can successfully be embolized using IMPEDE-FX embolization plugs as part of the treatment strategy. Prospective trials on patients with non-thrombosed false lumina are indicated.
ISSN:2520-8934
2520-8934
DOI:10.1186/s42155-020-00183-6