Simulations of the stationary Q = 10 and the exit phase from the flat-top of an ITER 15MA baseline scenario: predictive JINTRAC simulation with a consistent treatment of D and T in the whole plasma
Designing a robust termination scenario for a burning ITER plasma is a challenge that requires extensive core plasma and divertor modelling. The presented work consists of coupled core/edge/SOL/divertor simulations, performed with the JINTRAC code, to study the Q = 10 flat-top phase and exit phase o...
Gespeichert in:
Veröffentlicht in: | Nuclear fusion 2024-12, Vol.64 (12), p.126033 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Designing a robust termination scenario for a burning ITER plasma is a challenge that requires extensive core plasma and divertor modelling. The presented work consists of coupled core/edge/SOL/divertor simulations, performed with the JINTRAC code, to study the Q = 10 flat-top phase and exit phase of the ITER 15 MA/5.3 T DT scenario. The modelling utilizes the recently implemented option to treat deuterium and tritium separately in the SOL/divertor, enabling a consistent treatment of deuterium and tritium in the whole plasma volume, which is a unique capability of JINTRAC. In addition, these are the first JINTRAC simulations of this scenario that use a first-principles transport model to self-consistently model the ECRH power deposition and to include tungsten while keeping track of tungsten sputtering and accumulation. The flat-top simulations demonstrate the possibility of sustaining a steady state fusion Q of 10 using pure deuterium gas puffs together with DT mixed pellets, which is an option to make a more effective use of tritium. Simulations of the exit phase are set up sequentially, with each phase providing initial conditions for the next, starting with a density decay at full current and auxiliary power, and demonstrate the possibility of reducing the density robustly within a few seconds. Following the density decay, a subsequent auxiliary power ramp-down in H-mode is performed with a late H–L transition at low auxiliary power, which may provide an option for the optimization of the plasma termination. The final ramp-down phase consists of a current ramp-down in L-mode to 3.75 MA. |
---|---|
ISSN: | 0029-5515 1741-4326 1741-4326 |
DOI: | 10.1088/1741-4326/ad7c63 |