Demonstration of a laserwire emittance scanner for hydrogen ion beams at CERN

A noninvasive, compact laserwire system has been developed to measure the transverse emittance of an H− beam and has been demonstrated at the new LINAC4 injector for the LHC at CERN. Light from a low power, pulsed laser source is conveyed via fiber to collide with the H− beam, a fraction of which is...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physical review special topics. PRST-AB. Accelerators and beams 2015-12, Vol.18 (12), p.122801, Article 122801
Hauptverfasser: Hofmann, T., Kruchinin, K. O., Bosco, A., Gibson, S. M., Roncarolo, F., Boorman, G., Raich, U., Bravin, E., Pozimski, J. K., Letchford, A., Gabor, C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A noninvasive, compact laserwire system has been developed to measure the transverse emittance of an H− beam and has been demonstrated at the new LINAC4 injector for the LHC at CERN. Light from a low power, pulsed laser source is conveyed via fiber to collide with the H− beam, a fraction of which is neutralized and then intercepted by a downstream diamond detector. Scanning the focused laser across the H− beam and measuring the distribution of the photo-neutralized particles enables the transverse emittance to be reconstructed. The vertical phase-space distribution of a 3 MeV beam during LINAC4 commissioning has been measured by the laserwire and verified with a conventional slit and grid method.