Implantable "loop recorder"--a new diagnostic tool for syncope of unknown cause

The implantable loop recorder (ILR) is a new diagnostic tool in cardiology for establishing the causes of unexplained syncope in patients where standard conventional tests, invasive tests included, have failed. The device is a diagnostic "pacemaker," surgically implanted underneath the ski...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Srpski arhiv za celokupno lekarstvo 2005-07, Vol.133 (7-8), p.338-342
Hauptverfasser: Milasinovic, Goran, Zivkovic, Mirjana, Jovanovic, Velibor, Jelic, Vera, Savic, Dragutin, Pavlovic, Sinisa, Calovic, Zarko
Format: Artikel
Sprache:eng ; srp
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The implantable loop recorder (ILR) is a new diagnostic tool in cardiology for establishing the causes of unexplained syncope in patients where standard conventional tests, invasive tests included, have failed. The device is a diagnostic "pacemaker," surgically implanted underneath the skin of the chest, with leads attached to the case of the device, not requiring endovenous lead implantation. Heart rhythm is monitored continuously on the basis of an endless loop, up to a maximum period of 14 months. Recording is carried out either by applying an outside activator whenever symptoms occur, or automatically, according to a pre-set algorithm for bradycardia, tachycardia, and/or asystolic detection. The aim of this study was to present this new diagnostic method as well as our first experiences with its implementation. We followed 5 patients (3 male, 2 female, mean age: 46.4 +/- 19) who had ILRs ("Reveal Plus," Medtronic Inc., USA) implanted at our centre, over a period of 14 months (7.6 +/- 5.5), concentrating on their clinical course, symptom occurrence, and electronically monitored heart rhythm at the time of ILR auto activation and/or recordings triggered by outside activation whenever a patient's symptoms were discernible. In three patients, the ILR revealed syncope aetiology by documenting heart rhythm at the time of its occurrence. In one patient, involving a lethal outcome, the ILR was not explanted, so that the rhythm at the time of the fatal syncope, although assumed, remained undocumented. In one, most recently implanted patient, follow-up is still in progress. The implantable loop recorder represents an important innovation and a step forward in establishing the causes of recurrent syncope, which cannot be determined by standard invasive and non-invasive testing.
ISSN:0370-8179
2406-0895