Extent and Distribution of Parenchymal Abnormalities in Baseline CT-Scans Do Not Predict Awake Prone Positioning Response in COVID-19 Related ARDS

Prone positioning is frequently used for non-intubated hypoxemic patients with COVID-19, although conclusive evidence is still lacking. The aim of the present study was to investigate whether baseline CT-scans could predict the improvement in oxygenation in COVID-19 related Acute respira-tory syndro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostics (Basel) 2022-07, Vol.12 (8), p.1848
Hauptverfasser: Raimondi, Federico, Cazzaniga, Sara, Annibali, Simona, Novelli, Luca, Brivio, Matteo, Pappacena, Simone, Malandrino, Luca, Bonaffini, Pietro Andrea, Bianco, Ilaria, Liggeri, Noemi, Gritti, Paolo, Lorini, Ferdinando Luca, Sironi, Sandro, Di Marco, Fabiano
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Prone positioning is frequently used for non-intubated hypoxemic patients with COVID-19, although conclusive evidence is still lacking. The aim of the present study was to investigate whether baseline CT-scans could predict the improvement in oxygenation in COVID-19 related Acute respira-tory syndrome (ARDS) patients when pronated. Methods: A retrospective study of COVID-19 patients who underwent non-invasive ventilation (NIV) and prone positioning was conducted. Results: Forty-five patients were included. On average, 50% of the overall lung volume was affected by the disease, as observed in the CT-scans, with ground glass opacities (GGOs) and consolidations accounting for 44% and 4%, respectively. The abnormalities were mainly posterior, as demonstrated by posterior/anterior distribution ratios of 1.5 and 4.4 for GGO and consolidation, respectively. The median PaO2/FiO2 ratio during NIV in a supine position (SP1) was 140 [IQR 108–169], which improved by 67% (+98) during prone positioning, on average. Once supine positioning was resumed (SP2), the improvement in oxygenation was maintained in 28 patients (62% of the overall population, categorized as “responders”). We found no significant differences between responders and non-responders in terms of the extent (p = 0.92) and the distribution of parenchymal abnormalities seen in the baseline CT (p = 0.526). Conclusion: Despite the lack of a priori estimation of the sample size, considering the absence of any trends in the differences and correlations, we can reasonably conclude that the baseline chest CT-scan does not predict a gas-exchange response in awake prone-positioned patients with COVID-19 related ARDS. Physicians dealing with this category of patients should not rely on the imaging at presentation when evaluating whether to pronate patients.
ISSN:2075-4418
2075-4418
DOI:10.3390/diagnostics12081848