Failure mode analysis of electronic detonator under high overload condition
Under different overload conditions, the split Hopkins method was used to test the high overload performance of the electronic detonator and the failure status of each electronic detonator component was obtained. The results show that the power supply function of the electronic control module in the...
Gespeichert in:
Veröffentlicht in: | FirePhysChem (Online) 2022-06, Vol.2 (2), p.199-205 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Under different overload conditions, the split Hopkins method was used to test the high overload performance of the electronic detonator and the failure status of each electronic detonator component was obtained. The results show that the power supply function of the electronic control module in the delayed state has a short failure when the starting value of overload is 6.23 ten thousand g, and the greater the overload, the more obvious the failure. When the overload increases to 38.10 ten thousand g, the communication function of the electronic control module fails. When the overload increases to 46.62 ten thousand g, the riveting part is still firm without failure.
Under different overload conditions, the split Hopkins method was used to test the high overload performance of electronic detonator and the failure status of each electronic detonator component was obtained.
[Display omitted] |
---|---|
ISSN: | 2667-1344 2667-1344 |
DOI: | 10.1016/j.fpc.2022.02.001 |