A comparison of chemiluminescent immunoassay and enzyme-linked immunosorbent assay for detecting phospholipase A2 receptor antibody in primary membranous nephropathy
The accurate detection of phospholipase A2 receptor (PLA2R) autoantibody is crucial in the diagnosis and monitoring of primary membranous nephropathy (pMN). While enzyme-linked immunosorbent assay (ELISA) is the commonly used detection method, its complexity and time-consuming nature pose challenges...
Gespeichert in:
Veröffentlicht in: | Practical laboratory medicine 2024-03, Vol.39, p.e00385-e00385, Article e00385 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The accurate detection of phospholipase A2 receptor (PLA2R) autoantibody is crucial in the diagnosis and monitoring of primary membranous nephropathy (pMN). While enzyme-linked immunosorbent assay (ELISA) is the commonly used detection method, its complexity and time-consuming nature pose challenges, especially for small sample sizes. Chemiluminescence immunoassay (CLIA) has emerged as a rapid alternative for clinical immunoassays. This study aims to compare the sensitivity, specificity, and precision of CLIA and ELISA in detecting PLA2R autoantibody.
A total of 145 patients with biopsy-confirmed primary membranous nephropathy and 85 patients with non-membranous nephropathy were enrolled in this comparative study. CLIA and ELISA were employed to test all samples for the presence of PLA2R autoantibodies. Statistical analysis of sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) was performed using SPSS 26.0. The diagnostic value of ELISA and CLIA for pMN was analyzed using the ROC curve, and Correlation analysis was performed using Spearman.
Serum levels of anti-PLA2R antibody in pMN group were significantly higher than those in nMN group(P 0.05). The overall qualitative agreement of anti-PLA2R detection was 93.35% (95% confidence interval[CI] 89.47–96.3). ROC curve analysis showed that AUC of anti-PLA2R antibody detected by ELISA and CLIA were 0.8737 (95% confidence interval [CI] 0.8270–0.9204), 0.8914 (95% confidence interval [CI]0.8495–0.9332), respectively. The Spearman correlation analysis revealed a significant correlation between them(P |
---|---|
ISSN: | 2352-5517 2352-5517 |
DOI: | 10.1016/j.plabm.2024.e00385 |