Dose dependence of irradiation hardening of neutron irradiated vanadium alloys by using temperature control rig in JMTR

•Dose dependence of irradiation hardening for vanadium alloys in neutron irradiation is revealed.•The dynamic interaction between interstitial impurities and dislocation is not strong in V–4Cr–4Ti alloys in low temperature.•Effect of strain rate for yield stress and critical fracture stress affects...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear materials and energy 2016-12, Vol.9 (C), p.441-446
Hauptverfasser: Fukumoto, Ken-ichi, Onitsuka, Takashi, Narui, Minoru
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Dose dependence of irradiation hardening for vanadium alloys in neutron irradiation is revealed.•The dynamic interaction between interstitial impurities and dislocation is not strong in V–4Cr–4Ti alloys in low temperature.•Effect of strain rate for yield stress and critical fracture stress affects the fracture mode of neutron-irradiated V–4Cr–4Ti alloys. TEM observation and tensile test were examined for vanadium alloys irradiated in a temperature control rig in JMTR at 290°C with damage level ranged from 0.003 to 0.06dpa. With the increase of the neutron dose, irradiation hardening could be observed in all the vanadium alloys except for the V–5Nb alloy. In the case of pure vanadium, the relationship between irradiation hardening and neutron dose was described as Δσ ∝ (ϕt)0.35-0.53. For V–5Cr alloy and V–4Cr–4Ti–0.1Si alloy, the dose dependence on irradiation hardening increase was shown as Δσ ∝ (ϕt)0.8 and Δσ ∝ (ϕt)0.8-1.0, respectively. From the TEM observation, the hardening source of radiation-induced defects was mainly determined to be dislocation loops for pure vanadium, loops with voids for V–5Cr and, loops and {100} precipitates for V–4Cr–4Ti–0.1Si and V–3Fe–4Ti–0.1Si alloys. From the strain rate dependence of 8% stress for V–4Cr–4Ti–0.1Si alloys tested at RT, the strain rate sensitivity, m=1/σ*(dσ/dln(dε/dt)) shows positive. Therefore, the dynamic interaction between interstitial impurities and dislocation is not strong in V–4Cr–4Ti alloys in the temperature range from RT to 290°C. A discrepancy of deformation mode of irradiated V–4Cr–4Ti–0.1Si alloys with 0.068dpa could be seen when the charpy impact test indicated the brittle behavior and the tensile test indicated the ductile behavior at room temperature. It can be explained by the difference of strain rate for the value of yield stress between tensile test and charpy test and the critical fracture stress.
ISSN:2352-1791
2352-1791