Valgus Malalignment Due to Internally Malrotated Trochanteric Nail Placement, with Rotational Malalignment in Femoral Shaft Segmental Fracture Fixation, an Underestimated Avoidable Technical Error: A Case Report

Coronal malalignment due to malrotated trochanteric nail placement in femoral fracture fixation has never been reported. We present a case of a femoral segmental fracture fixed with a trochanteric nail, with a malrotated placement resulting in a valgus malaligned nail and femur, associated with a ro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Malaysian orthopaedic journal 2020-03, Vol.14 (1), p.74-77
Hauptverfasser: Hwang, P X, Anuwar, N A, Khaw, Y C, Hadizie, D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Coronal malalignment due to malrotated trochanteric nail placement in femoral fracture fixation has never been reported. We present a case of a femoral segmental fracture fixed with a trochanteric nail, with a malrotated placement resulting in a valgus malaligned nail and femur, associated with a rotational malalignment. Knowledge of the modern nail design with proper intra-operative precautions, would avoid this underestimated technical error.