Establishment and application of a multiplex genetic mutation-detection method of lung cancer based on MassARRAY platform

Objective: This study aims to establish a method for highly parallel multiplexed detection of genetic mutations in Chinese lung cancer samples through Agena i PLEX chemistry and matrix-assisted laser desorption ionization time-of-flight analysis on Mass ARRAY mass spectrometry platform.Methods: We r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cancer biology & medicine 2016-03, Vol.13 (1), p.68-76
Hauptverfasser: Tian, Hong-Xia, Zhang, Xu-Chao, Wang, Zhen, Chen, Jian-Guang, Chen, Shi-Liang, Guo, Wei-Bang, Wu, Yi-Long
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective: This study aims to establish a method for highly parallel multiplexed detection of genetic mutations in Chinese lung cancer samples through Agena i PLEX chemistry and matrix-assisted laser desorption ionization time-of-flight analysis on Mass ARRAY mass spectrometry platform.Methods: We reviewed the related literature and data on lung cancer treatments. We also identified 99 mutation hot spots in 13 target genes closely related to the pathogenesis, drug resistance, and metastasis of lung cancer. A total of 297 primers, composed of99 paired forward and reverse amplification primers and 99 matched extension primers, were designed using Assay Design software. The detection method was established by analyzing eight cell lines and six lung cancer specimens. The proposed method was then validated through comparisons by using a Lung Carta^TM kit. The sensitivity and specificity of the proposed method were evaluated by directly sequencing EGFR and KRAS genes in 100 lung cancer cases.Results: The proposed method was able to detect multiplex genetic mutations in lung cancer cell lines. This finding was consistent with the observations on previously reported mutations. The proposed method can also detect such mutations in clinical lung cancer specimens. This result was consistent with the observations with Lung Carta~(TM) kit. However, an FGFR2 mutation was detected only through the proposed method. The measured sensitivity and specificity were 100% and 96.3%, respectively.Conclusions: The proposed Mass ARRAY technology-based multiplex method can detect genetic mutations in Chinese lung cancer patients. Therefore, the proposed method can be applied to detect mutations in other cancer tissues.
ISSN:2095-3941
2095-3941
DOI:10.20892/j.issn.2095-3941.2015.0094